FLEX R495 3kW Trusted Colo

Rating
495,00 
(589,05  inc tax)
Deployment time1 to 3 working days Werktage Contract period6 months TCO for complete term (net, at 80% power consumption)5648 € Energy costs per kWh00:25 € / kW/h Energy costs included in the price as a flat rateNo Connection / cooling capacity per rack3 kW
Shipping time and rates:
Vendor rating
Rate vendor
Our advantages
Options
Vertragslaufzeit 6 Monate
495,00 
Monthly
6

Wavelength and VLAN to Frankfurt and Düsseldorf on request.

Trusted-Colo GmbH & Co. KG has been operating its own data center since 2020
in Alsbach-Hähnlein in southern Hesse.
The location is easily accessible via the A5, A67 and B3.

The data center is designed as TIER III +. Electricity, air conditioning and data line
are fully redundant.

Due to the location and the German owner and operator, the
German data protection guaranteed.

All racks (47U, 600x1000mm) are designed as cold aisles and with A + B feed
supplied with 3 kW. Up to 15 kW can be provided per rack.

Other rack sizes or cages are possible upon customer request.

after the corresponding utilization, the PUE (including electricity) will be below 1.3.

Deployment time:
1 to 3 working days Werktage
Contract period:
6 months
TCO for complete term (net, at 80% power consumption):
5648
Data center energy costs (including all charges)
Energy costs per kWh:
00:25 € / kW/h
Energy costs included in the price as a flat rate :
No
Data center racks
Connection / cooling capacity per rack:
3 kW
Rack type:
1/1 rack (whole rack)
Rack depth:
100 cm
Rack width:
60 cm
Rack height (usable U):
47 U
Rack locking system:
Mechanical closure
Rack redundancy power supply:
2N (redundant A + B power supply)
Stromzuführung:
Einphasig 16A
Air conditioning redundancy:
2N + 1
PDU A Typ:
Einfache PDU, unmanaged
PDU B Typ:
Einfache PDU, unmanaged
Data center energy efficiency
Design PUE:
1.3
Data center sustainability
Electricity from renewable sources:
Regenerative Energie wird als Zertifikat eingekauft:
Betreiber erzeugt selbst regenerative Energie:
Nutzung Abwärme des RZ:
Errichtung des RZ mit nachhaltigen Materialien:
Nachhaltige Materialien zertifiziert:
Used refrigerant:
R410A
Data center SLA
Power availability for redundantly connected customers:
99,999 %
Power availability basis:
Monthly mean
Guaranteed availability of air conditioning:
99.99 %
Guaranteed supply air temperature minimum:
22.7 °C
Guaranteed supply air temperature maximum:
23.3 °C
Guaranteed minimum humidity:
45 % rF
Guaranteed maximum humidity:
65 % rF
Guaranteed availability network connection / IP transit:
99.9 %
Availability network connection basis:
Annual mean
Availability / SLA reports:
Yearly
General data center
Type of building:
Dedicated building
Construction:
Solid construction (concrete / stone)
storage areas:
parking :
Covered delivery:
Truck loading ramp / lifting table:
Temporary jobs:
Permanent jobs for rent:
Use of meeting rooms possible:
Temporary storage space:
Permanently rentable storage space:
Raised floors in the data center areas:
Soil is dissipative:
Floor area load:
12th kN per m2
Point load floor:
8th kN
Clear room height of IT rooms:
350 cm
Clear height transport routes (minimum) :
250 cm
Data center in airport approach lane:
No
Data center near train tracks:
No
Data center near the motorway:
No, at least 500m away
Data center in floodplain:
No
Data center in earthquake zone:
Zone 1
Data center in the vicinity of potentially explosive facilities:
No
Data center close to other hazards:
No
Data center security
Protection / zone concept was implemented:
Burglary protection building outer shell:
RC 3
Burglary protection IT rooms:
RC 3
Burglary protection technical operating rooms:
RC 3
Burglary protection security center:
RC 3
Fenced off area:
Fence with step over protection:
Fence and gate monitored by sensors:
Fence and gate under video surveillance:
Apron surveillance with video:
Apron monitoring with additional sensors:
Approach protection building:
Burglar alarm system building outer shell:
Burglar alarm system IT areas:
Burglar alarm system technical operating rooms:
Intrusion alarm system for traffic areas:
Video surveillance building outer shell:
Video surveillance IT areas:
Video surveillance of technical operating rooms:
Video surveillance traffic areas:
Separation system / lock building access:
Isolation system / sluice IT rooms:
Separation system / lock technical operating rooms:
Electronic access control system:
Two-factor verification (card + pin, etc):
Biometric verification:
Security Staff:
No security service on site
Security Service on call:
Data center fire protection
Walls of IT rooms:
F90
Doors IT rooms:
T30
Walls of technical operating rooms:
F90
Doors for technical operating rooms:
T30
Wall openings sealed in wall class:
Floor coverings flame-retardant / non-combustible:
Fire alarm system with smoke detectors:
Fire alarm system with combination detectors (smoke, heat):
IT rooms with RAS system (early fire detection):
Technical operating rooms with RAS system (early fire detection):
IT rooms with extinguishing systems or oxygen reduction:
Technical operating rooms with extinguishing system or oxygen reduction:
Switching off the fresh air system in the event of a fire outside the building:
Halogen-free flooring:
Halogen-free cable:
Data center supply infrastructure
Voltage level mains supply:
Medium voltage
Redundancy power grid:
Supply from a substation
Medium voltage supply redundancy:
  • Ring feed
Medium voltage main distribution redundancy:
N (no redundancy)
Transformer redundancy:
N (no redundancy)
Backup redundancy system:
2N
Redundancy of storage tanks:
2N
Separate tank for each emergency power system:
Network replacement system fuel supply:
More than 48 hours of operation
UPS system redundancy:
2N + 1
Batteries:
Multi-strand
Low voltage distributions redundancy:
2N
Sub-distributions / busbars in IT rooms redundancy:
2N
Power rails in IT rooms:
Cable routing from transformer to IT rooms:
Redundant, structurally and separately in terms of fire protection
Type of air conditioning:
Cold water, chiller, ULK
Air conditioning redundancy devices:
2N
Redundancy pipe network (if available):
2N
Redundancy pumps (if available):
2N
Lightning protection:
Protection class I
Data center network and connectivity
Network building supply:
Redundant routing, separated structurally and in terms of fire protection
Network cable routing in the building:
Redundant routing, separated structurally and in terms of fire protection
Network distributor / meet-me rooms:
Redundant, structurally and separately in terms of fire protection
Active network components:
2N
Total IP transit capacity:
80 Gbit/s
Upstream carriers used:
DTAG, HE-NET, and others
Exchange points that you have connected yourself:
DE-CIX, KLEY-REX, Opencarrier
Data center hyperscaler connectivity
Amazon AWS:
Bandwidth:
10 Gbit / s
Google Cloud Plattform:
Microsoft Azure:
Bandwidth:
10 Gbit / s
IBM Bluemix / Softlayer:
VMWare VCloud Air:
Oracle:
Alibaba:
Data center certifications
ISO 9001:
ISO 27001:
ISO 50001:
Data center services
Access to the data center:
24x7
Remote hands (reset, opt. Test, etc.):
  • During business hours
Extended remote hands (reboot, patch, etc.):
During business hours
Hardware support (HDD, power supply, etc.):
During business hours
Atdn. service for service providers:
During business hours
Web tool for tickets and orders:
Acceptance of customer shipments:
Unpacking / packing service, dispatch of goods:
Rack installation of customer equipment:
During business hours
Documentation / labeling of devices and cabling:
Web-based documentation system for customers:
Network equipment support:
During business hours
Creation of a service report:
Per month
Other services offered:
Back
Other services offered:
Security
Other services offered:
DDOS protection

Service Level Agreement (DEFINI~2.PDF, 62 Kb) [Download]

Definition Stromananschluss (Definition3_Stromanschluss.pdf, 102 Kb) [Download]

No posts found

0
%
Criteria Average rating Count of ratings
How reliable is the vendor?
How is the communicatin with the vendor?
How transparent is the vendor?
How fair is the vendor?
  • Popular
  • Recently viewed
  • New