28.7 kW Airsys Chillrow Inrow cooler for data centers, water-cooled
Please sign in so that we can notify you about a reply
Airsys Chillrow 28.7 kW - CW water-cooled (type CW25C1)
Including filter sensor, floor water sensor, condensate pump, RS485 to TCP / IP converter
Further equipment variants on request.
The precision cooling units of the Airsys CHILLROW series offer precise and targeted cooling for data center applications. The CHILLROW devices are installed between the server cabinets and direct cold air into the cold aisle. Used as a stand-alone or as part of a larger CRAC unit installation, areas with high local heat density can be effectively addressed by the horizontal supply arrangement of the CHILLROW units, which increases the performance and efficiency of the overall cooling solution.
1 Coordinated design CHILLROW devices are available in 2 housing widths | 7 Electric heater and humidifier Electric heating and humidifiers are not included in the standard version |
2 supply air requirements The short horizontal airway through the devices, with a front | 8 Serviceability Service access is provided through both the front and the back of the devices, making both situations routine |
3 options for heat dissipation The CHILLROW series is an air-cooled DX device (DXA) | 9 Easy installation CHILLROW devices have been designed for easy maneuvering in tight spaces |
4 Environmentally friendly refrigerant R410A is used in DXA units and has a | 10 high flexibility The small dimensions and the horizontal supply air arrangement |
5 Double drip tray The first stainless steel drip tray is below | 11 Reduced operating costs Thanks to the defined intermediate rack arrangement of the CHILLROW devices |
6 condensate water pump
| |
Functional scheme
Chillrow.DXA
Heat from the indoor air is transferred to the refrigerant at the evaporator and to the air-cooled condenser
the outside air is released. The air-cooled DX application (DXA) includes the configuration of the expansion valve, evaporator, scroll compressor and refrigerant line.
Chillrow.CW
The CW unit is equipped with a cold water register and a 2-way or 3-way control valve including an actuator
and connected to an external cooling water source. The valve modulates according to the cooling requirement
to ensure optimized efficiency. The server heat is absorbed by the chilled water and over
the chiller released into the environment.
Technical specifications
A selection of our references
No posts found
-
AIRSYS-CHILLROW-SB-V1.0.pdf (9,556 Kb)