Deployment time4 to 6 weeks Werktage Contract period36 months TCO for complete term (net, at 80% power consumption)38649 € Energy costs per kWh00:28 € / kW/h Energy costs included in the price as a flat rateNo Connection / cooling capacity per rack2.5 kW
Options
Shipping time and rates:
Vendor rating
Rate vendor
Our advantages

TeleData SPACE Co-Locate

Are you looking for an access and fail-safe environment for your IT systems? Then let TeleData advise you. We have state-of-the-art data centers that meet the latest security standards. With TeleData SPACE Co-Locate, TeleData offers you the optimal space for your server. You benefit from redundant technical building equipment and a fast and reliable internet connection. As well as the elimination of maintenance and operation.

The most important features at a glance:

  • Modern data center, designed according to Tier 3 standard
  • Provision of energy supply, air conditioning and network
  • Maintenance and operation of the entire technical building equipment
  • Access-protected rooms / premises; Access to the data center (24/7)
  • Service around the clock - on-call service 24 hours, 7 days a week
  • Smoke alarm system and extinguishing system
  • Uninterruptible power supply (UPS) included
  • Additional service "remote hands" if required
  • Optional: Use of other infrastructure services (e.g. storage, computer ...)
Deployment time:
4 to 6 weeks Werktage
Contract period:
36 months
TCO for complete term (net, at 80% power consumption):
38649
Data center energy costs (including all charges)
Energy costs per kWh:
00:28 € / kW/h
Energy costs included in the price as a flat rate :
No
Data center racks
Connection / cooling capacity per rack:
2.5 kW
Anschluss- / Kühlleistung erweiterbar bis:
6 kW
Rack type:
1/1 rack (whole rack)
Rack depth:
120 cm
Rack width:
80 cm
Rack height (usable U):
42 U
Rack locking system:
Electronic locking
Rack redundancy power supply:
2N (redundant A + B power supply)
Air conditioning redundancy:
N + 1
PDU A Typ:
PDU messbar
PDU A outlets C13:
24
PDU A outlets C19:
4th
PDU B Typ:
PDU messbar
PDU B outlets C13:
24
PDU B outlets C19:
4th
Data center energy efficiency
Design PUE:
1.6
Operationally measured PUE (12 months):
1.6
Data center sustainability
Electricity from renewable sources:
Source regenerative sources:
Water and wind
Regenerative Energie wird als Zertifikat eingekauft:
Betreiber erzeugt selbst regenerative Energie:
Nutzung Abwärme des RZ:
Errichtung des RZ mit nachhaltigen Materialien:
Nachhaltige Materialien zertifiziert:
Used refrigerant:
water
Data center SLA
Guaranteed total availability:
99.98 %
Power availability for redundantly connected customers:
99.98 %
Guaranteed availability of air conditioning:
99.98 %
Guaranteed supply air temperature minimum:
22.0 °C
Guaranteed supply air temperature maximum:
24.0 °C
Guaranteed minimum humidity:
40 % rF
Guaranteed maximum humidity:
65 % rF
Guaranteed availability network connection / IP transit:
99.98 %
Availability network connection basis:
Annual mean
Availability / SLA reports:
Yearly
General data center
Type of building:
Dedicated building
Construction:
Solid construction (concrete / stone)
storage areas:
parking :
Covered delivery:
Truck loading ramp / lifting table:
Temporary jobs:
Permanent jobs for rent:
Use of meeting rooms possible:
Temporary storage space:
Permanently rentable storage space:
Raised floors in the data center areas:
Soil is dissipative:
Floor area load:
24 kN per m2
Point load floor:
5 kN
Clear room height of IT rooms:
249 cm
Clear height transport routes (minimum) :
198 cm
Data center in airport approach lane:
No
Data center near train tracks:
No
Data center near the motorway:
No, at least 500m away
Data center in floodplain:
No
Data center in earthquake zone:
No
Data center in the vicinity of potentially explosive facilities:
No
Data center close to other hazards:
No
Data center security
Protection / zone concept was implemented:
Burglary protection building outer shell:
RC 2
Burglary protection IT rooms:
RC 2
Burglary protection technical operating rooms:
RC 2
Burglary protection security center:
RC 2
Fenced off area:
Fence with step over protection:
Fence and gate monitored by sensors:
Fence and gate under video surveillance:
Apron surveillance with video:
Apron monitoring with additional sensors:
Approach protection building:
Burglar alarm system building outer shell:
Burglar alarm system IT areas:
Burglar alarm system technical operating rooms:
Intrusion alarm system for traffic areas:
Video surveillance building outer shell:
Video surveillance IT areas:
Video surveillance of technical operating rooms:
Video surveillance traffic areas:
Separation system / lock building access:
Isolation system / sluice IT rooms:
Separation system / lock technical operating rooms:
Electronic access control system:
Two-factor verification (card + pin, etc):
Biometric verification:
Security Staff:
No security service on site
Security Service on call:
Data center fire protection
Walls of IT rooms:
F90
Doors IT rooms:
T90
Walls of technical operating rooms:
F90
Doors for technical operating rooms:
T90
Wall openings sealed in wall class:
Floor coverings flame-retardant / non-combustible:
Fire alarm system with smoke detectors:
Fire alarm system with combination detectors (smoke, heat):
IT rooms with RAS system (early fire detection):
Technical operating rooms with RAS system (early fire detection):
IT rooms with extinguishing systems or oxygen reduction:
Technical operating rooms with extinguishing system or oxygen reduction:
Switching off the fresh air system in the event of a fire outside the building:
Halogen-free flooring:
Halogen-free cable:
Data center supply infrastructure
Voltage level mains supply:
Medium voltage
Redundancy power grid:
Supply from a substation
Medium voltage supply redundancy:
  • Ring feed
Medium voltage main distribution redundancy:
N (no redundancy)
Transformer redundancy:
N (no redundancy)
Backup redundancy system:
N (no redundancy)
Redundancy of storage tanks:
N
Separate tank for each emergency power system:
Network replacement system fuel supply:
More than 48 hours of operation
UPS system redundancy:
N + 1
Batteries:
Single strand
Low voltage distributions redundancy:
N (no redundancy)
Sub-distributions / busbars in IT rooms redundancy:
2N
Power rails in IT rooms:
Cable routing from transformer to IT rooms:
Redundant routing
Type of air conditioning:
Cold water, chiller, in-row
Air conditioning redundancy devices:
N + 1
Redundancy pumps (if available):
N + 1
Lightning protection:
Protection class II
Data center network and connectivity
Network building supply:
Redundant routing, separated structurally and in terms of fire protection
Network cable routing in the building:
Redundant routing, separated structurally and in terms of fire protection
Network distributor / meet-me rooms:
Redundant, structurally and separately in terms of fire protection
Active network components:
2N
Total IP transit capacity:
120 Gbit/s
Upstream carriers used:
CenturyLink, Tata Communications, KPN, Cogent, Deutsche Telekom
Exchange points that you have connected yourself:
DE-CIX, AMS-IX, ECIX, KleyRex, Stuttgart-IX
Available carriers for Layer 1,2,3 Connectivity:
TeleData, Telekom
Data center hyperscaler connectivity
Amazon AWS:
Google Cloud Plattform:
Microsoft Azure:
IBM Bluemix / Softlayer:
VMWare VCloud Air:
Oracle:
Alibaba:
Data center certifications
ISO 9001:
ISO 27001:
ISO 50001:
Data center services
Availability of remote hands:
  • 24x7 start time <15 minutes
Access to the data center:
24x7
Remote hands (reset, opt. Test, etc.):
  • 24x7
Extended remote hands (reboot, patch, etc.):
24x7
Hardware support (HDD, power supply, etc.):
24x7
Atdn. service for service providers:
24x7
Web tool for tickets and orders:
Acceptance of customer shipments:
Unpacking / packing service, dispatch of goods:
Rack installation of customer equipment:
No installation service
Documentation / labeling of devices and cabling:
Web-based documentation system for customers:
Network equipment support:
24x7
Other services offered:
Public & private cloud
Other services offered:
Managed storage
Other services offered:
S3 storage
Other services offered:
Managed Linux / Win Server
Other services offered:
Managed firewall
Data center access and staff
Access to the data center:
  • 24h / 7 days
operating staff:
  • 24h / 7 days on site