DC08 Rack - ready to use

Contact us for a price
Our quantity discounts:
Quantity
2+
Price
799,00 €
Energy costs per kWh00:22 € / kW/h Connection / cooling capacity per rack4 kW
Shipping time and rates:
Vendor rating
Rate vendor
Our advantages
Monthly
12
Monthly
24
Monthly
36
Monthly
48
Monthly
60

Server room / rack

  • Two server rooms in separate fire zones.
  • Available in the data center up to 300 m² of rental space.
  • Redundant power supply per rack.
  • Power consumption between 4 kW and 20 kW per rack.
  • Real-time measurement of electricity consumption.
  • Redundant, needs-based air conditioning with cold aisle containment.
  • Optional customization of the racks, such as B. Access, sensors (temperature, humidity, air pressure, door condition).
  • Consideration of individual customer requests.

safety

  • Safety fence with protection against climbing over.
  • Sliding gate system with access card reader, traffic lights and bollard system.
  • Security personnel on site.
  • Access security on all relevant doors, with card and code or biometric access control.
  • Inside and outside visual building surveillance including IT and technical rooms.
  • Redundant data connection via separate routes.
  • Continuous 24/7 function monitoring of the data center infrastructure.

Fire protection

  • Separate fire compartments within the data center and the technical areas.
  • Two-stage fire alarm system.
  • Ultra-modern extinguishing system with nitrogen.
  • There is a lightning protection HVI system on the entire building complex.
  • Lightning and surge protection according to DIN EN 62305-5.

Power supply

  • Own transformer station.
  • Redundant low-voltage main distribution boards.
  • Modular UPS systems (double design).
  • Network replacement unit with fuel supply for 72 hours and supply contracts.
  • PUE value <1.3.

Availability

  • High availability class n + 1.
  • Minimum availability of 99.98%.
  • TÜV certified.

service

  • 24/7 access to the data center.
  • Acceptance of customer goods deliveries including intermediate storage.
  • Rental of means of transport and tools.
  • Complete assembly service with installation, conversion and expansion.
  • "Helping hands" by highly qualified, own operating staff.
  • Manual storage of common cables on site.
  • Provision of customer warehouses.
  • Support from external service providers on request.
  • Delivery of hardware (server, storage, network) without operating system.
  • Occupancy and cable planning including inventory documentation.
  • Provider-neutral internet connectivity.

Data center energy costs (including all charges)
Energy costs per kWh:
00:22 € / kW/h
Data center racks
Connection / cooling capacity per rack:
4 kW
Rack type:
1/1 rack (whole rack)
Rack installation with warm / cold aisle separation:
Yes
Rack PDU:
  • 400V / 32A (three-phase)
  • Active PDU
  • Measuring function (power and consumption) infeed
  • Measuring function (output and consumption) per outlet
  • Outlets can be switched remotely
Rack depth:
120 cm
Rack width:
80 cm
Rack height (usable U):
46 U
Rack load capacity:
1,000 kg to 1,500 kg
Rack locking system:
Mechanical closure
Rack redundancy power supply:
2N (redundant A + B power supply)
General data center
Type of building:
Dedicated building
Data center security
Security Staff:
Outside business hours on siteNo security service on site
Data center supply infrastructure
Medium voltage supply redundancy:
  • Redundant stitch feed
Network replacement system fuel supply:
More than 48 hours of operation
UPS system redundancy:
2N
Low voltage distributions redundancy:
2N
Type of air conditioning:
Cold water, chiller, ULK
Air conditioning redundancy devices:
N + 1
Data center services
Availability of remote hands:
  • 15 to 30 minutes during business hours
  • Outside business hours, arrival time 31 to 60 minutes
Data center access and staff
Access to the data center: