comtrance FullRack Colocation Rack Datacenter Düsseldorf
Please sign in so that we can notify you about a reply
The highly available comtrance colocation data center in Connecta Parc in Düsseldorf - Eller offers companies and resellers the opportunity to rent IT racks or private data center space in the highly secure colocation area and operate them themselves.
Our highlights:
- Secure hosting in a German data center
- DIN ISO 9001: 2008
- DIN EN 27001: 2008
- Own, independent data center
- Multiple redundant internet connection
- Up to 99.999% SLA availability
- 24/7 premium support
- Premium hardware
- MS Windows © and Linux operating systems
- Citrix Xen, Xen, KVM, VMware ©
- Dedicated cloud backup and storage
- Shared cloud backup and storage
Access to the data center in Düsseldorf.
Physical access to the data center in Düsseldorf is only possible for authorized persons. The identity is checked by means of RFID readers and a biometric hand scanner and only authorized persons are granted access to the data center in Düsseldorf.
Construction.
The data center in Düsseldorf has exterior and interior walls in solid construction. It is also equipped with self-closing doors. The colocation areas are equipped with a double floor (600 mm rectangular panels, with a height of up to 500 mm). Access to the data center in Düsseldorf is at ground level, so that the equipment can be transported without problems.
Video surveillance system.
The entire data center in Düsseldorf is camera-monitored around the clock. The cameras are located at all entrances to the data center as well as in the colocation areas themselves. All recordings are saved and archived over a predefined period of time.
Alarm / fire alarm system.
The data center in Düsseldorf is equipped with an alarm system. In this way, all entrance areas and particularly critical zones are protected against unauthorized access. Furthermore, the entire data center in Düsseldorf has a modern early fire detection system, which detects a possible fire both above and below the raised floor and initiates the appropriate measures. Both systems are connected to a local security service and are monitored remotely.
Connection.
»Multiple redundant carrier connections
»Various fiber optic cables to transfer points of the most important carriers in Connecta Parc
Redundant building entry.
Both for the power supply as well as for the Internet connections,
the data center in Düsseldorf has redundant and separate building entries.
Air conditioning.
The air conditioning takes place via the double floor. The air conditioning systems used are specially designed for use in data centers and, in addition to optimal cooling, also ensure a minimal risk of condensation. The inlet air conditioning is 24 ° C ± 2 ° C, 50% RH ± 20 and is subject to constant monitoring. The cooling capacity of the individual air conditioning systems is approx. 50 kW.
Uninterruptible power supply.
To ensure a permanent power supply, particular importance was attached to a high degree of availability and redundancy in the energy supply. The power is permanently buffered by redundant UPS systems, which not only result in complete power failures, but also power fluctuations in the energy supplier's networks to be balanced.
Emergency generator.
An emergency power generator is available for longer power outages and supplies up to 100% of the electricity if required. Appropriate control mechanisms ensure that components with high starting currents such as motor loads and rectifiers are started one after the other. The generator has a start-up time of around 30 seconds and is checked and tested for functionality once a month. The fuel supply is designed for permanent operation of the emergency power generator. Refueling during operation is also possible in order to be able to bridge longer downtimes.
- 15 to 30 minutes during business hours
- Outside business hours, arrival time 15 to 30 minutes
- 24x7