Janitza electronics GmbH

Vendor products Products found: 15

52.32.010
     
Location:

222,00  (264,18  inc tax)
In stock
14.020.16
     
Location:

99,00  (117,81  inc tax)
In stock
254,00  (302,26  inc tax)
In stock
254,00  (302,26  inc tax)
In stock
Energy monitoring for your data center HIGH AVAILABILITY Monitor high availability Verify network quality Monitor redundancies Avoid shutdowns FIRE PROTECTION AND EMC Monitor fault currents ENERGY EFFICIENCY represent losses Calculate workloads Key figures and forecasts benchmarks COST CENTER MANAGEMENT Calculate energy costs
Location:

Contact us for a price
In stock
723,00  (860,37  inc tax)
In stock
     
Location:

2847,00  (3387,93  inc tax)
In stock
52.16.202
     
Location:

828,00  (985,32  inc tax)
In stock
     
Location:

1150,00  (1368,50  inc tax)
In stock
14.02.025
Modular energy meter for DIN rail mounting Suitable for measuring in all levels of TN & TT networks as well as in IT networks with voltage transformers to record current, voltage, frequency, active, apparent, & reactive power (per phase & total) in the frequency range 45 - 65 Hz, power factor & cos phi, referred reactive & apparent energy as well as referred and delivered active energy (4-quadrant measurement) in separate memory values, continuous true effective value measurement (True RMS).   Can be expanded with a maximum of one expansion module of the type "Module 806-EC1", "Module 806-EI1" and "Module 806-ED1" that can be plugged in on the right side. A maximum of 3 expansion modules of different module types can be connected to a basic device.  
Location:

299,00  (355,81  inc tax)
In stock
52.32.001
     
Location:

414,00  (492,66  inc tax)
In stock
52.32.004
     
Location:

523,00  (622,37  inc tax)
In stock
52.26.001
     
Location:

1147,00  (1364,93  inc tax)
In stock
14.01.625
Operating and residual current measuring device with 20 channels and memory for DIN rail mounting.   Supply voltage 90-264V AC (50/60Hz) / 120-350V DC   Dimensions: 90.105x72, (6 TE) for 20 current transformer inputs for CT6-20, SCT-20, CT20, 4 voltage inputs with continuous sampling of the voltage and current measurement inputs   Operating data: Rated voltage (insulation coordination according to IEC 60664-1) AC 300 V, rated impulse voltage 4 kV, overvoltage category III, degree of pollution 3, Supply voltage, AC/DC 70..276 V 50/60 Hz Own consumption 3 watts Monitored System Instrument transformer types / transformation ratio: Operating current measuring transformer: Splitcore SCT20 3000/1, CT-6-20 700/1, CT20 700/1 Residual current measuring transformer: CT-6-20 700/1, CT20 700/1   Measuring channels / evaluation: Number of measuring channels: 24 (4x voltage L1,L2, L3, N / 20x current measuring transformer) Measured value acquisition: parallel, real effective value measurement (True RMS), Sampling rate: (all channels) 20 kHz Cut-off frequency: (all channels) 3 kHz Current measurement channel function: individually configurable per channel as operating current or residual current Measurements: voltages / operating currents / differential currents Evaluation: voltage, current, active power, apparent power, Reactive power, phase shift, real work, MIN and MAX, cost centers Number of harmonics: 63.OS odd Data transfer Measured values: in V, A, kW, kVA, kVar, cosf, kWh Evaluation range operating current: 0..63 A Evaluation range residual current: 0..1000 mA Connection monitoring: Each input has a converter connection control   Parameterization: Configurable values per channel: warning and response thresholds / hysteresis range for response thresholds, Delay times: Delay of the warning and response messages: (0 .. 10 s) Reset delay of response and warning messages: tvr (0 .. 10 s)   Displays and messages: Displays: 27 LEDs, 3 states per LED Messages: LED / digital outputs / RS485   Digital outputs (open collector): Number: 2 External wiring: relay / PLC inputs Output current max. / output 350 mA External voltage source: (auxiliary voltage) UC 24 V   Communication Interface / Protocol: Interface / protocol: RS485 (AB,GND) not isolated / Modbus RTU (slave) Setting range from 9600 baud to 921600 baud   Environmental conditions: Ambient temperature (during operation): according to EN 61557-8: 1997 -5 .. +55°C Ambient temperature (during storage): according to EN 61557-8: 1997 -25 .. +70°C Climatic class according to IEC 7213K5, without condensation and icing   Delivery including: Installation accessories, documentation, coordination of the design with the practical application and the measured variables including their recording intervals, compatible residual current transformer set, configuration and parameterization of the device, delivery, installation and Connection.   Make: Janitza electronics GmbH Type: UMG20CM Item No. 1401625 Unit: piece Item No .: 1401625
Location:

1221,00  (1452,99  inc tax)
In stock
52.36.001
     
Location:

482,00  (573,58  inc tax)
In stock

Presentations

Imagebroschüre
Download
Broschüre Rechenzentrum
Download
Broschüre Differenzstrom (RCM)
Download

Certificates & References

REACH DE
Download
REACH EN
Download
ISO9001 DE
Download
ISO9001 EN
Download
ISO50001 DE
Download
ISO50001 EN
Download
Umweltstatement DE
Download
Environmental statement EN
Download
Verwendung von Konfliktrohstoffen DE
Download
use of conflict commodities EN
Download
Code of Conduct DE
Download
Code of Conduct
Download

Janitza electronics GmbH

Vor dem Polstück 6
Lahnau
35633
Ask a question
0
%
Criteria Average rating Count of ratings
How reliable is the vendor?
How is the communicatin with the vendor?
How transparent is the vendor?
How fair is the vendor?

No posts found